Model: RF-IT

Model: RF-IT

Above Ground Insulator Tester / RF-IT

Features

  • Hand Held Instrument
  • Easily locates shorted bolts, replaces bolt to bolt
  • Use on structure with or without CP
  • Uses Radio Frequency to test effectiveness of above ground insulators
  • Auto Shut-Off feature

Includes

  • Probe, Red with lead wire and needle point tip
  • Probe, Black with needle point tip
  • Additional needle tips, stored in small black vinyl tubes
  • (6) AA Batteries
  • Instructions Manual
  • Warranty Card

 

Broşür İndrimek İçin Tıklayınız

Model: RF-IT

 

Radio Frequency instrument allows testing on structures under protection. Audible beep gets faster the closer to the point of contact. Use needle tipped probes to move bolt to bolt to find contact.

 

Model: RF-IT

 

 

IMPORTANT NOTE:

Do not use this instrument in an explosive environment.

 

Model: RF-IT

 

 

Use

Test above ground pipeline insulators to pinpoint the precise contact point. The RF-IT emits an audible beep. When the operator gets closer to the point of contact the unit starts beeping faster. At the same time, the LCD meter moves from left to right.

 

      Specifications       Dimensions
  • Battery Operated
  • Operating: 8" x 4" x 3", 2 lbs. (203mm x 101.6mm xc 76.2mm, 0.907kg)
  • (6) Alkaline "AA" batteries (replaceable)
 
  • Cables and probes included
 

 

Model: RF-IT

 

     Parts List

  • #085-113 RF-IT Instrument 
  • #005-150 Assembly Probe Red w/Wire Lead 
  • #005-151 Assembly Probe Black  
  • #118-048 Tip Needle Point 
  • #010-002 Battery, "AA" Cell  Each RF-IT Takes Six AA's Each